Canon PIXMA MX340 Series Simplified Service Manual - Page 12

Browse online or download pdf Simplified Service Manual for All in One Printer Canon PIXMA MX340 Series. Canon PIXMA MX340 Series 35 pages. Cartridge reset
Also for Canon PIXMA MX340 Series: Installation Manual (17 pages), Install Manual (11 pages), Network Setup Manual (26 pages), Brochure (2 pages), Manual (8 pages), Manual (10 pages), Network Setup Troubleshooting (13 pages), Network Installation Manual (16 pages), Connection Manual (11 pages), Manual (4 pages)

Canon PIXMA MX340 Series Simplified Service Manual
Error
TX /
code
RX
##780 TX
After transmitting EOR-EOM in ECM transmission,
no significant signal has been received, and
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##782 TX
After transmitting EOR-EOM in ECM transmission,
DCN has been received.
##783 TX
After transmitting EOR-EOM in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
##784 TX
After transmitting EOR-EOM in ECM transmission,
ERR has been received.
##785 TX
After transmitting EOR-EOP in ECM transmission,
no significant signal has been received, and
re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##787 TX
After transmitting EOR-EOP in ECM transmission,
DCN has been received.
##788 TX
After transmitting EOR-EOP in ECM transmission,
re-transmission of the procedure signal has been
attempted the number of specified times but failed,
or T5 time-over (60 sec.) has occurred.
##789 TX
After transmitting EOR-EOP in ECM transmission,
ERR has been received.
##790 RX
After receiving EOR-EOP in ECM reception, ERR
has been transmitted.
##791 TX /
During the ECM mode procedure, a signal other
RX
than a significant one has been received.
##792 RX
In ECM reception, PPS-NULL between partial
pages has not been detected.
##793 RX
During high-speed signal reception in ECM, no
effective frame has been detected, and a time-over
has occurred.
Meaning
(11/37)
Solution
(parts that are likely to be faulty)
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Increase the transmission level of the
receiving machine.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Increase the transmission level of the
sending machine.
- Increase the transmission level of the
sending machine.
- Try a higher transmission level.
- Increase the transmission level of the
sending machine.