Canon PIXMA MX700 Series Service Manual - Page 11
Browse online or download pdf Service Manual for All in One Printer Canon PIXMA MX700 Series. Canon PIXMA MX700 Series 44 pages. Office all-in-one printer
Also for Canon PIXMA MX700 Series: Cleaning Manual (7 pages), Network Setup Manual (32 pages), Supplementary Manual (6 pages), Setup Instructions (2 pages), Brochure & Specs (2 pages), Technical Information (2 pages)
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##769
TX
After transmitting PPS-EOP in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##770
TX
After transmitting EOR-NULL in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##772
TX
After transmitting EOR-NULL in ECM transmission, DCN has been received.
##773
TX
After transmitting EOR-NULL in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##774
TX
After transmitting EOR-NULL in ECM transmission, ERR has been received.
##775
TX
After transmitting EOR-MPS in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##777
TX
After transmitting EOR-MPS in ECM transmission, DCN has been received.
##778
TX
After transmitting EOR-MPS in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##779
TX
After transmitting EOR-MPS in ECM transmission, ERR has been received.
##780
TX
After transmitting EOR-EOM in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##782
TX
After transmitting EOR-EOM in ECM transmission, DCN has been received.
##783
TX
After transmitting EOR-EOM in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##784
TX
After transmitting EOR-EOM in ECM transmission, ERR has been received.
##785
TX
After transmitting EOR-EOP in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##787
TX
After transmitting EOR-EOP in ECM transmission, DCN has been received.
##788
TX
After transmitting EOR-EOP in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##789
TX
After transmitting EOR-EOP in ECM transmission, ERR has been received.
##790
RX
After receiving EOR-EOP in ECM reception, ERR has been transmitted.
##791
TX / RX During the ECM mode procedure, a signal other than a significant one has been received.
##792
RX
In ECM reception, PPS-NULL between partial pages has not been detected.
##793
RX
During high-speed signal reception in ECM, no effective frame has been detected, and a time-over has
occurred.
9 / 41