AMES SILVER BULLET 3000SS Series Installation Instructions

Browse online or download pdf Installation Instructions for Control Unit AMES SILVER BULLET 3000SS Series. AMES SILVER BULLET 3000SS Series 4 pages. Double check valve, assemblies & double check detector assemblies

Series 2000SS/SE & 3000SS/SE
Double Check Valve
Assemblies & Double
Check Detector
Assemblies
1
Sizes: 2
/
" – 6"SS (65 – 150mm)
2
6" – 8"SE (150 – 200mm)
• Installation
• Service
• Repair Kits
• Maintenance
Installation Note: The flange gasket bolts for
the gate valves should be retightened during
installation as the bolts may have loosened
due to storage and shipping.
A Division of Watts Water Technologies, Inc.
1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333
Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service.
Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and
modifications on Ames products previously or subsequently sold.
2000SS
For other repair kits and service parts, send for
Ames Repair Parts Price List, PL-A-RP-BPD.
For technical assistance, contact your local
Ames representative.
IMPORTANT: Inquire with governing
authorities for local installation requirements.
NOTE: For Australia and New Zealand, line
strainers should be installed between the
upstream shutoff valve and the inlet of the
backflow preventer.
Its important that this assembly be tested
periodically in compliance with local codes,
but at least once per year or more as service
conditions warrant. If installed on a fire
sprinkler system, all mechanical checks,
such as alarm checks and backflow
preventers, should be flow tested and
inspected internally in accordance with NFPA
13 and NFPA 25.
Limited Warranty: Ames Company warrants each product
to be free from defects in material and workmanship
under normal usage for a period of one year from the date
of original shipment. In the event of such defects within
the warranty period, the Company will, at its option,
replace or recondition the product without charge. This
shall constitute the sole and exclusive remedy for breach
of warranty, and the Company shall not be responsible for
any incidental, special or consequential damages,
including without limitation, lost profits or the cost of
repairing or replacing other property which is damaged if
www.amesfirewater.com
RP/IS-A-2000SS/SE&3000SS/SE
this product does not work properly, other costs resulting
from labor charges, delays, vandalism, negligence, fouling
caused by foreign material, damage from adverse water
conditions, chemical, or any other circumstances over
which the Company has no control. This warranty shall be
invalidated by any abuse, misuse, misapplication or
improper installation of the product. THIS WARRANTY IS
IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. Any implied warranties that are imposed by
law are limited in duration to one year.
Some States do not allow limitations on how long an
implied warranty lasts, and some States do not allow
the exclusion or limitation of incidental or consequential
damages. Therefore the above limitations may not
apply to you. This Limited Warranty gives you specific
legal rights, and you may have other rights that vary
from State to State. You should consult applicable state
laws to determine your rights.