Temperature Measurement

Measure temperature from 32
to 1832
F (0
to 1000
°
°C
1.
Connect red end of Thermocouple
(included) to the Input Jack and
the black end to the COM Jack.
2.
Turn Rotary Switch to the Temp
position. The Display will show the
current ambient temperature.

Resistance Measurement

Measure circuit resistance up to 66M Ohms.
WARNING! To prevent electric shock, turn
off all power and fully discharge capacitors
on the circuit under test before measuring.
Note: When measuring Ohms,
start with the lowest range if the
resistance is unknown.
1.
Plug black test lead into COM Jack.
Plug red test lead into Input Jack.
2.
Turn the Rotary Switch
to the
position.
3.
Carefully touch exposed
conductors with tips of probes.
4.
Read measured resistance
on the Display.
Item 64019
°F
C).
°
For technical questions, please call 1-888-866-5797.
3.
Press FUNC to switch between
Celsius and Fahrenheit.
4.
Touch the tip of the Thermocouple
to the object to be tested.
5.
Read measured temperature
on the Display.
WARNING! To prevent electric
shock, remove Thermocouple before
switching between testing modes.
5.
When testing is complete, turn
Rotary Switch to OFF, remove
Test Leads and store with Meter.
Note: Sometimes the resistor value and
measured resistance differ. This is due
to the Meter's output test current going
through all possible paths between leads.
Note: For resistance measurements
above 1MΩ, allow a few seconds
to get a steady reading.
Note: When leads are disconnected
or measurement is out of
range, OL is displayed.