DC Voltage
DC Voltage Accuracy
DC Current
DC Current Accuracy
AC Voltage
AC Voltage Accuracy
AC Current
AC Current Accuracy
Resistance
Resistance Accuracy
Capacitance
Capacitance Accuracy
Diode
Continuity
Frequency
Frequency Accuracy
Temperature
Temperature Accuracy
Low Impedance (Lo-Z)
Lo-Z Accuracy
Duty Cycle
Duty Cycle Accuracy
Operating Temperature
Display
Battery
Item 64019
Ranges: 660mV / 6.6V / 66V / 660V / 1000V
(@660mV) ± 0.8% of rdg + 3D
(@6.6V - 660V) ± 0.5% of rdg + 5D
(@1000V) ± 0.8% of rdg + 3D
Ranges: 660μA / 6600μA / 66mA / 660mA / 10A
(@660μA - 660mA) ± 1.0% of rdg + 5D
(@10A) ± 2.0% of rdg + 5D
Ranges: 660mV / 6.6V / 66V / 660V / 1000V
Frequency Range:
(@660mV) 40-60Hz;
(@6.6V - 1000V) 40-400Hz
(@660mV) ± 1.5% of rdg + 5D
(@6.6V - 66V) ± 1.2% of rdg + 5D
(@660V - 1000V) ± 1.0% of rdg + 3D
Ranges: 660μA / 6600μA / 66mA / 660mA / 10A
Frequency Range: 40-400Hz
(@660μA - 660mA) ± 1.5% of rdg + 5D
(@10A) ± 3.0% of rdg + 5D
Ranges: 660Ω / 6.6kΩ / 66kΩ / 660kΩ / 6.6MΩ / 66MΩ
(@660Ω - 6.6MΩ) ± 0.8% of rdg + 5D
(@66MΩ) ± 1.5% of rdg + 5D
Ranges: 6.6nF / 66nF / 660nF / 6.6μF / 66μF / 660μF / 6.6mF / 66mF
(@6.6nF) ± 4.0% of rdg + 5D
(@66nF - 660μF) ± 3.0% of rdg + 3D
(@6.6mF - 66mF) ± 4.0% of rdg + 5D
Forward DC Current: ~1mA
Reverse DC Voltage: ~3.2V
Meter beeps at < 50Ω
Hz% Mode:
66Hz - 10kHz
Voltage Mode: 66Hz - 66MHz
Voltage Mode: ± 1.5% of rdg + 5D
Hz% Mode:
± 1.5% of rdg + 5D
Range: 32°F - 1832°F (0°C - 1000°C)
(@32°F - 1832°F) ± 1.0% of rdg + 3D
Ranges: 660mV / 6.6V / 66V / 660V / 1000V
(@660mV) ± 1.5% of rdg + 5D
(@6.6V - 66V) ± 1.2% of rdg + 5D
(@660V - 1000V) ± 1.0% of rdg + 3D
1%-99%
± 2.0%
Range: 32°F - 104°F (0°C - 40°C)
LCD
9V (Included)
For technical questions, please call 1-888-866-5797.