Plumbing Connections
This AKW M11 DigiPump is rated for:
Max Head: 1.0m (39in)
Max Lift: 0.5m (19in)
Combined Lift and Head: 1.5m (59in) MAX.
For best performance locate within 1m (39in) of shower
and minimise the number of lifts, bends and the length of
all pipes connecting the Pump to the waste outlet pipe.
Note: Increased Head/Lift conditions will affect the pump's performance.
Shower Head
Shower Tray
MINIMISE PIPEWORK LENGTH WHEREVER POSSIBLE
NOT PREFERRED
Important: For service & maintenance purposes this product must be installed in
an accessible location. Pipe connections must be easily accessed.
Important: All external pipe connections must be at least 100mm (4in) clear and
suitable for pump removal.
Guest International Limited.
PREFERRED (NO ELBOWS)
®
ALWAYS
Pipe inserts.
100mm (4in)
MIN GAPS
®
9
Waste outlet
pipe
OR
Use the supplied Pipe
Adaptors to connect
to waste outlet pipe.
locking collars.