Astria Fireplaces 900005-07 Installation Instructions - Page 2

Browse online or download pdf Installation Instructions for Fireplace Accessories Astria Fireplaces 900005-07. Astria Fireplaces 900005-07 2 pages. Framing standoff and vent gasket

INNOVATIVE HEARTH PRODUCTS • SIGNATURE
Figure 2: Attaching the right side framing standoff
3. Align the left side of the framing standoff with the left side of
the fireplace (Figure 3). Secure the standoff with two (2) of
the included 5/16 in. screws in the holes closest the side of
the fireplace.
f i r e - p a r t s . c o m
NOTE: The ends of the framing standoffs will overlap.
Figure 3: Attaching the left side framing standoff
Screws
4. Position the center support as shown (Figure 4), with
the larger screw holes oriented to the bottom. Secure
with two (2) of the included 5/16 in. screws in the top
and two (2) 5/16 in. screws in the bottom of the center
support.
Innovative Hearth Products reserves the right
to make changes at any time, without notice,
in design, materials, specifications, prices and
also to discontinue colors, styles, and products.
Consult your local distributor for fireplace
code information Printed in U.S.A. © 2014
Innovative Hearth Products, LLC.
P/N 900005-07 Rev. A 10/2014
SERIES DIRECT-VENT GAS FIREPLACES • ENVY/ENVY CD 35/40/45TEN • INSTALLATION INSTRUCTIONS
®
Screws
P900005-07
Figure 4: Installing the center support
TOP VENT ROPE GASKET INSTALLATION INSTRUCTIONS
1. Slide the rope gasket over the top vent component and
position it snugly against the apppliance (Figure 5).
Figure 5: Installing the rope gasket
AFTER INSTALLING THE KIT
1. Reinstall the media/logs (if applicable) and the glass door.
2. Refer to the Installation Instructions (P/N 900005-00)
for information regarding turning ON the gas supply,
reconnecting the power supply at the circuit breaker, and
additional framing information.
Screws
Screws
Rope Gasket
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
IHP.US.com