COLDBUSTER FLOORHEATING CB Smart2 Instructions Manual - Page 8
Browse online or download pdf Instructions Manual for Thermostat COLDBUSTER FLOORHEATING CB Smart2. COLDBUSTER FLOORHEATING CB Smart2 10 pages.
No.
Name
11
12
Open Window
13
Power Set
Energy Use
14
15
Sensor Type
Factory Reset
16
1. Room Temperature Calibra�on:
Calibrate the temperature detected by the room sensor.
2. Floor Temperature Calibra�on:
Calibrate the temperature detected by the floor sensor.
3&4. An�-frozen Func�ons:
If the An�-frozen func�ons are turned on, the room and floor will
be kept at a lower temperature to protect pets and plants in your house.
5. Floor Temperature Limit:
When you choose both sensors, you can set the maximum floor
temperature value so the system will stop hea�ng if the floor temperature exceeds this value.
6. Temperature Tolerance:
The default range is 1°C.
11
Default
Ranges
ON/OFF
OFF
OFF
ON/OFF
0W -- 4500W
0 W
0-3950
1-3380
0-3950
2-3700
3-3600
4-3740
NO
NO/YES
7. Temperature Unit:
Switch around °F and °C.
8: Sensor Selec�on
Room sensor:
Run by room sensor.
Floor sensor:
Run by floor sensor.
Both sensors:
Run by room sensor with floor limit mode.
9. Schedule:
Select a weekly schedule for an event.
7:
Each day from Mon to Sun can be set individually.
5+1+1:
Mon to Fri have the same events, Sat and Sun can be set individually.
10. Output Delay:
This op�on helps you avoid inadvertent opera�on on hea�ng.
11. Adap�ve Func�on:
A�er several days of use, this op�on ensures that the required temperature has already
been reached when the next event begins.
12. Open Window:
This func�on only works when room sensor or both sensors are selected. The thermostat with this
func�on will shut off automa�cally for 15min, when it detects that the room temperature has plummeted.
13&14. Power Set and Energy Use:
This op�on allows you to enter the various data used to calculate energy use.
15. Sensor Type:
This thermostat is compa�ble with the following five floor temperature sensors.
(the default sensor is 0-3950 ).
12