No.
Name
11
12

Open Window

13
Power Set
Energy Use
14
15

Sensor Type

Factory Reset
16
1. Room Temperature Calibra�on:
Calibrate the temperature detected by the room sensor.
2. Floor Temperature Calibra�on:
Calibrate the temperature detected by the floor sensor.
3&4. An�-frozen Func�ons:
If the An�-frozen func�ons are turned on, the room and floor will
be kept at a lower temperature to protect pets and plants in your house.
5. Floor Temperature Limit:
When you choose both sensors, you can set the maximum floor
temperature value so the system will stop hea�ng if the floor temperature exceeds this value.
6. Temperature Tolerance:
The default range is 1°C.
11
Default
Ranges
ON/OFF
OFF
OFF
ON/OFF
0W -- 4500W
0 W
0-3950
1-3380
0-3950
2-3700
3-3600
4-3740
NO
NO/YES
7. Temperature Unit:
Switch around °F and °C.
8: Sensor Selec�on
Room sensor:
Run by room sensor.
Floor sensor:
Run by floor sensor.
Both sensors:
Run by room sensor with floor limit mode.
9. Schedule:
Select a weekly schedule for an event.
7:
Each day from Mon to Sun can be set individually.
5+1+1:
Mon to Fri have the same events, Sat and Sun can be set individually.
10. Output Delay:
This op�on helps you avoid inadvertent opera�on on hea�ng.
11. Adap�ve Func�on:
A�er several days of use, this op�on ensures that the required temperature has already
been reached when the next event begins.
12. Open Window:
This func�on only works when room sensor or both sensors are selected. The thermostat with this
func�on will shut off automa�cally for 15min, when it detects that the room temperature has plummeted.
13&14. Power Set and Energy Use:
This op�on allows you to enter the various data used to calculate energy use.
15. Sensor Type:
This thermostat is compa�ble with the following five floor temperature sensors.
(the default sensor is 0-3950 ).