Diagnostics port Service displays

Operational display. basic module (GM)
Once the mains power has been switched on, the power supply unit is energised. This takes about 20 seconds,
after which the LED lights up.
LED-display
e
0
C
e=
LED on
Function display. expansion module:
LED 1 and LED 2 signal an interrupted light barrier transmission path. LEDs light up prior to each closing cycle
during the light barrier test.
E5901l00
Condition
Function
Normal mode - Mains power available,
Normal mode
Off
unit not receiving mains power
Flashing (frequency 2 Hz)
Learning cycle - parameters are being determined and stored
o
0=
LED off
=
LED flashing
power supply unit energised
~
nORMA