DOTWORKZ HD12-CD-HB Installation Instructions Manual - Page 10

Browse online or download pdf Installation Instructions Manual for Security Camera DOTWORKZ HD12-CD-HB. DOTWORKZ HD12-CD-HB 16 pages.

3.2 Install the supplied domed lens on the hinged lid of the enclosure. Remove the 12 x 6-32 flat
head screws and set aside in a safe place for reinstallation. Remove the metal retaining ring to
expose the seal. Remove the protective film from the domed lens and align the mounting holes
of the dome with the holes in the gasket. Place the retaining ring over the domed lens and align
the holes of the retaining ring with the mounting holes in the domed lens. Reinstall the twelve
6-32 flat head screws and torque them to the appropriate value, making sure to alternate from
one side of the lens to the other when tightening the 12 screws to minimize stresses in the
domed lens.
12 X 6-32
FLAT HEAD
SCREWS
3.3 Plan your cable management before installing the enclosure. Pay particular attention to bend
radii and sealing of cable glands. The cable glands installed on the enclosure can be used as
plugs or break through, multi-hole glands for smaller diameter cables. The cable glands provided
in the hardware kit are designed to accommodate 1 cable per cable gland. The cable diameters
accommodated are 4.3 mm – 11.4 mm. Other cable diameters will require alternative cable
glands to create an environmental seal. It may be required to cut connectors off of terminated
cables and re-terminate a connector on the opposite side of the gland if a connector does not fit
through the prescribed gland.
RETAINING RING
DOMED LENS
10