Power input (line) wiring
The DMX24DIM should be connected to a standard 15A 120VAC grounded outlet. The
outlet must be protected by an appropriate over-current protection device.
Note that if all outputs are loaded to 100W and all outputs are set to full, the 15A
branch breaker feeding the DMX24DIM will trip. If the application requires all dimmers
to be fully loaded, the DMX24DIM must be fed by a 20A branch breaker and an
appropriate receptacle. The standard 15A mains plug on the DMX24DIM must be
replaced with an appropriate 20A connector.
Power output (load) wiring
Each output can supply a 100W (maximum) 120VAC load. Each output uses a
polarized ungrounded parallel blade connector (NEMA1-15R). Cables should only be
connected and disconnected while the dimmer outputs are off or the input power to the
DMX24DIM is removed.
Control cable wiring
Standard 5 pin XLR cables should be used to connect DMX512 signals to the
connectors on the front panel of the DMX24DIM. A male input is provided and a
passive female "thru" output is provided. There is no internal termination. The last
device in the DMX512 daisy chain should be fitted with a DMX512 terminator.
Only pins 1, 2, and 3 are used by the DMX24DIM, however all 5 pins are passed
through to the "thru" connector.