4.3.5.3 Center Aligned
A compromise between left and right aligned. The hysteresis is aligned symmetrical around the individual set
points.
Figure 16 Center Aligned, Single Point Mode

Hysteresis Width

4.3.6
The hysteresis is configured in percent of the switch point distance. It is the difference between switch point
and reset point. This parameter can be beneficial to smoothen out signals when samples have quickly
changing positions.
Figure 18 Hysteresis is the difference between switch point and reset point
Bright blue: object moving from far to close distance (in this case switch point)
-
Dark blue: moving from close to far distance (in this case reset point)
-
Parameter name
Hysteresis.SSC1 Width

Time filter

4.3.7
This changes the timing of the switching signals, for example to avoid bouncing/suppress false switching
operation. The ability to directly parametrize and configure the timing on the sensor itself, removes the need
to have additional coding on the PLC or to use pulse stretching adapters.
The described time filters can be configured and applied to each SSC individually.
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Short Description
Adjust hysteresis width as percent
of the switch point distance
15/40
Figure 17 Center Aligned, Window Mode
Rights
Unit / Allowed values
Limits 0 ... 99 %, Default 5%
rw