In section 3.1, the signal path is described more detailed, to illustrate how the counter module is
implemented. In section 4.3.8.2 the behavior is explained.
4.3.8.1 SSC4 Configuration
In general the SSC4 offers the same features as the SSC1 and SSC2 based on distance (See 4.3.2),
including also time filters.
Exceptions:
No hysteresis settings as there are only incremental counts.
-
Additional parameters to adjust like SSC4 Source and SSC4 Auto-Reset.
-
Parameter name
SSC4 Param.SP1
SSC4 Param.SP2
Parameter name
SSC4 Config.Logic
SSC4 Config.Mode
SSC Source
Settings.SSC4 Selection
SSC Source
Settings.SSC4 Auto
Reset
Parameter name
Release Delay.SSC4
Time
Response Delay.SSC4
Time
Minimal Pulse
Duration.SSC4 Time
Minimal Pulse
Duration.SSC4 Mode
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Short Description
Set the number of counts at which
the SSC is set to active (or
inactive if inverted)
Set the number of counts at which
the SSC is set to inactive (or
active if inverted). only active if
SSC is set to window mode
Short Description
Selects the SSC logic. It can be
changed between active if object
is present (normal) or inactive if
object is present (inverted)
Selection of the switching mode
Select the switch counter that is
used as input of SSC4
Auto Reset of switch counter if
value in SSC4 Param.SP1 is
reached
Short Description
Sets / indicates the release delay
time in milliseconds for the
respective switching signal
channel (SSC).
Sets / indicates the response
delay time in milliseconds for the
respective switching signal
channel (SSC).
Sets / indicates the minimal pulse
length in milliseconds for the
respective switching signal
channel (SSC).
0: Both Pulses: positive and
negative pulses are prolonged; 1:
Positive Pulse: only positive
pulses are prolonged; 2: Negative
Rights
rw
rw
Rights
rw
rw
rw
rw
Rights
rw
rw
rw
rw
19/40
Unit / Allowed values
0 ... max = 2147483639
Counts, default 20
0 ... max = 2147483639
Counts, default 0
Unit / Allowed values
- Normal (Default)
- Inverted
- Disabled (Default)
- Single Point
- Window
- SSC1 Switch Counter
(Default)
- SSC2 Switch Counter
- Enabled (Default)
- Disabled
Unit / Allowed values
0 to 60000 ms
Default: 0 ms
0 to 60000 ms
Default: 0 ms
0 to 60000 ms
Default: 0 ms
- Both Slopes (Default)
- Positive Slope
- Negative Slope