Baumer OM30 Operating Manual - Page 34

Browse online or download pdf Operating Manual for Accessories Baumer OM30. Baumer OM30 48 pages. Laser distance sensors

Baumer OM30 Operating Manual
8
|
Functions
8.9

Function of the output

The IO-Link communication principle can also be used as a switching output. In the factory set-
tings, the function of the output is equivalent to the alarm output. This means that the output is
activated as soon as no measured value can be recorded. Through IO-Link this can be switched
to a switching output than can be parameterized.
IO-Link parameter: Output
Parameter name
DI/DO Settings.OUT 1 Mode
8.10

Analog measurement field

With the Analog measurement field function, you can define the resolution of the analog output
by moving the limits of the analog measurement field. When the analog measurement field is
limited, smaller distance changes can be displayed.
The function can be configured via the following parameters:
Min. limit of the analog measurement range (factory setting: Sdc)
n
Max. limit of the analog measurement range (factory setting: Sde)
n
Ill. 20: Analog measurement field (factory setting)
Sdc
P1
ZP
You have the option of inverting the characteristic curve of the analog measurement field.
Ill. 21: Analog measurement field – inverted
34
Sdc
measurement field
ZP
P1
Start of the measurement range
Min. limit of the analog measurement
range
Zero position
Sdc
Sde
Operating Manual
Values
SSC1 - Alarm,
SSC1 - Switch State
Sde
Analog
P2
Sde
P2
not inverted (pos. sensitivity)
inverted (neg. sensitivity)
Distance
Description
Select the function of the output.
End of the measurement range
Max. limit of the analog measurement
range
Baumer
OM20/OM30 | V1