Baumer OM30 Operating Manual - Page 35

Browse online or download pdf Operating Manual for Accessories Baumer OM30. Baumer OM30 48 pages. Laser distance sensors

Baumer OM30 Operating Manual
Baumer
Examples of the behavior of the analog output
Behavior with invalid measured values: near
Characteristic curve inverted: no
Sdc
Behavior with invalid measured values: far
Characteristic curve inverted: no
Sdc
IO-Link parameter: Analog measurement field
Parameter name
AnalogSetting.Output Type
Distance@Analog Min
Distance@Analog Max
Output Characteristic
Baumer commands –
Output Scale at Analog Min
Baumer commands –
Output Scale at Analog Max
Baumer commands – Output
Scale is set to the possible max.
OM20/OM30 | V1
P1
P2
Sde
P1
P2
Sde
Values
4 ... 20 mA,
2 ... 10 mA/
0 ... 10 VDC,
0 ... 5 VDC
-
-
Not Inverted,
Inverted
-
-
-
Behavior with invalid measured values: near
Characteristic curve inverted: yes
Distance
Sdc
Behavior with invalid measured values: far
Characteristic curve inverted: yes
Distance
Sdc
Description
Configuring the range of the analog output
Enter the min. limit of the analog measure-
ment range (in mm)
Enter the max. limit of the analog mea-
surement range (in mm)
Inverting the analog output
Teach in min. limit of the analog measure-
ment range (alternatively to the Teach but-
ton)
Teach in max. limit of the analog mea-
surement range (alternatively to the Teach
button)
Set the analog measurement range to the
max. possible limits
Operating Manual
Functions
Sde
P1
P2
Sde
P1
P2
|
8
Distance
Distance
35