Also for Dahua F Series: Quick Start Manual (17 pages), Quick Start Manual (18 pages), Quick Start Manual (17 pages), Quick Start Manual (15 pages), Quick Start Manual (6 pages), Quick Start Manual (16 pages), Quick Start Manual (18 pages), Quick Start Manual (7 pages), Quick Start Manual (17 pages), Quick Start Manual (16 pages), Quick Start Manual (18 pages), Quick Start Manual (12 pages), Quick Start Manual (16 pages), Quick Start Manual (12 pages), Quick Start Manual (13 pages), Quick Start Manual (18 pages)

Dahua F Series Quick Start Manual
Dahua HD IR Bullet Network Camera Quick Start Guide
Please refer to the following figure for alarm output information. See Figure 1-5 and
Figure 1-6.
Mode A:
Level application. Alarm output high and low level, alarm output is OC; it needs to
increase pull-up resistance externally to work normally. Max external pull-up level is 12V,
max port current is 300mA (peak). After external pull-up resistance is increased, the
default output signal is high level (external pull-up voltage), and it switches to low level
when there is alarm output.
Mode B:
Switch application. Alarm output is used to drive external circuit, max voltage is 12V and
max current is 300mA (peak), it is recommended to add a relay if it is beyond the value.
Figure 1-5
Figure 1-6
4