6.1.1   CDN Selection 
 
The IEC‐61000‐4‐6 requires that an appropriate coupling decoupling networks (CDN) with 
defined common mode impedance be used for coupling and/or decoupling purposes on any 
type of power or I/O interface for which a CDN is suitable and available. The shielded T series 
CDNs are only appropriate for signal lines (ethernet). Other types CDNs available from Com‐
Power Corporation are given below. 
 
 
Model 
 
CDN‐M125E 
 
CDN‐M225E 
 
CDN‐M325E 
 
CDN‐M425E 
 
CDN‐M525E 
 
 
CDN‐C50E
 
 
CDN‐C75E
 
 
CDN‐S1
 
 
CDN‐S2
 
 
CDN‐S4
 
 
CDN‐S9
 
 
CDN‐S15
 
 
CDN‐S25
 
 
CDN‐AF2E
 
 
CDN‐AF4E
 
 
CDN‐AF8E
 
 
CDN‐T2E
 
 
CDN‐T4E
 
 
CDN‐T8E
 
19121 El Toro Rd ● Silverado, California 92676 ● (949) 459‐9600● com‐power.com
Shielded T‐series Coupling/Decoupling Networks (CDN) 
Specifications 
Single line, 25 Amp, 150 kHz ‐ 230 MHz 
Single line + Neutral, 25 Amp, 150 kHz ‐ 230 MHz 
Single line + Neutral + Earth, 25 Amp, 150 kHz ‐ 230 MHz 
Three phase + Neutral, 25 Amp, 150 kHz ‐ 230 MHz 
Three phase + Neutral+ Earth, 25 Amp, 150 kHz ‐ 230 MHz 
50 Ohm coax cable, 150 kHz ‐ 230 MHz
75 Ohm  coax cable, 150 kHz ‐ 230 MHz
Shielded cable with 1 conductor,150 kHz ‐ 80 MHz
Shielded cable with 2 conductors,150 kHz ‐ 80 MHz
Shielded cable with 4 conductors,150 kHz ‐ 80 MHz
Shielded cable with 9 conductors,150 kHz ‐ 80 MHz
Shielded cable with 15 conductors,150 kHz ‐ 80 MHz
Shielded cable with 25 conductors,150 kHz ‐ 80 MHz
Unshielded cable with 2 conductors,150 kHz ‐ 230 MHz
Unshielded cable with 4 conductors,150 kHz ‐ 230 MHz
Unshielded cable with 8 conductors,150 kHz ‐ 230 MHz
Unshielded cable with 2 conductors balanced pairs,150 kHz ‐ 230 MHz
Unshielded cable with 4 conductors balanced pairs,150 kHz ‐ 230 MHz
Unshielded cable with 8 conductors balance pairs,150 kHz ‐230 MHz
 