4.2
Connection of an encoder to the BiSS Adaptor
Use the programming cable included in the delivery to connect the encoder to the BiSS Adaptor. The
programming connector of the encoder is located under the locking screw on the encoder housing.
ATTENTION: When using an encoders with cable outlet (-5), the loose wires must not build contact to
eachother, otherwise no programming can be done!
Figure 9: Connection of encoder to BiSS Adaptor
HB EncoderMaster E V1.00.xx rev04.doc
10/15
Baumer Electric AG
09.07.08/wer