Baumer Hubner Berlin CANopen PMG 10 Installation And Operating Instructions Manual - Page 16
Browse online or download pdf Installation And Operating Instructions Manual for Media Converter Baumer Hubner Berlin CANopen PMG 10. Baumer Hubner Berlin CANopen PMG 10 28 pages. Absolute encoder with magnetic sensing
ELECTRICAL CONNECTION / CANOPEN®
Bus connecting box CANopen® [ A ] - Version with connectors
5.1.3
5.1.3.1
Connector M12 [C] (male, 5-pin, A-coded)
4
1
5.1.3.2
Connector M12 [D] (female, 5-pin, A-coded)
3
2
13/25
MALE
5
1
3
2
3
4
5
2
FEMALE CONNECTION DESCRIPTION
5
1
4
2
3
4
5
1
Bus connecting box
CANopen® [ A ]
[ C ] [ D ]
CONNECTION DESCRIPTION
GND
Ground for UB
UB
Voltage supply 10���30 VDC
GND
Ground for UB
CAN_H
CAN bus signal (dominant HIGH)
CAN_L
CAN bus signal (dominant LOW)
GND
Ground for UB
UB
Voltage supply 10���30 VDC
GND
Ground for UB
CAN_H
CAN bus signal (dominant HIGH)
CAN_L
CAN bus signal (dominant LOW)