Baumer HUBNER BERLIN DeviceNet HMG 10 Mounting And Operating Instructions - Page 18
Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HUBNER BERLIN DeviceNet HMG 10. Baumer HUBNER BERLIN DeviceNet HMG 10 36 pages. Absolute encoder with magnetic sensing
ELECTRICAL CONNECTION / DEVICENET
Bus connecting box DeviceNet [ A ] - Version with connectors
5.1.3
5.1.3.1
Connector M12 [C] (male, 5-pin, A-coded)
4
1
5.1.3.2
Connector M12 [D] (female, 5-pin, A-coded)
3
2
15/33
Bus connecting box
DeviceNet [ A ]
MALE
5
1
3
2
3
4
5
2
FEMALE CONNECTION DESCRIPTION
5
1
4
2
3
4
5
1
[ C ] [ D ]
CONNECTION DESCRIPTION
DRAIN
Shield
UB
Voltage supply 10���30 VDC
GND
Ground for UB
CAN_H
CAN bus signal (dominant HIGH)
CAN_L
CAN bus signal (dominant LOW)
DRAIN
Shield
UB
Voltage supply 10���30 VDC
GND
Ground for UB
CAN_H
CAN bus signal (dominant HIGH)
CAN_L
CAN bus signal (dominant LOW)
MB252EN - 11173969, 16A1, Baumer_HMG10-DeviceNet_II_EN