Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
6.2.3
ESL 93
(3 Relais-Treiber, 3 Schaltdrehzahlen)
6.2.3.1
Anschlussbelegung
Ansicht Y
Anschlussklemmen,
siehe Abschnitt 6.2.1.2.
View Y
Connecting terminal,
see section 6.2.1.2.
6.2.3.2
Blockschaltbild
G
3~
n
n
n
ESL 93
6.2.3.3
Empfohlene Ausgangsbeschaltung
6.2.3.4
Ausgangsschaltverhalten
12 VDC
out 1/2/3
-n
n =
Drehzahl / Speed
ns =
Eingestellte Schaltdrehzahl / Adjusted switching speed
MB071.2T2 - 11068774
1
2
3
R
/R
/R
1
2
3
ESL 93
0 V
0 V
-ns (1,2,3)
Baumer_HOG10-ESL-T2_II_DE-EN (20A1)
Elektrischer Anschluss / Electrical connection
6.2.3
ESL 93
(3 relay driver, 3 switching speeds)
6.2.3.1
Terminal assignment
Kabel:
5-adrig abgeschirmt,
Länge: ≤200 m bei
1 mm
2
Cable:
5 leads shielded,
length: ≤200 m at
1 mm
2
6.2.3.2
Block circuit diagram
COMP
COMP
COMP
6.2.3.3
Recommended output circuit
470
12 VDC
6.2.3.4
Switching characteristics
0
+ns (1,2,3)
Querschnitt
cross-section
U
= 12 VDC
R
0 V (GND)
R
1
0 V
R
2
0 V
R
3
0 V
out 1/2/3
+n
6
26