Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions - Page 30

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HUBNER BERLIN HOG 10. Baumer HUBNER BERLIN HOG 10 40 pages. Incremental encoder with connecting cable ölfle
Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
6
Elektrischer Anschluss / Electrical connection
6.2
ESL
6.2.4
ES 93 R
Relaismodul (Zubehör)
6.2.4.1
Anschlussbelegung
3 Kontroll-LED's
3 control LEDs
3 Relais/relays
≤6 A / 250 VAC
≤1 A / 48 VDC
6.2.4.2
Blockschaltbild
R1
R2
R3
6.2.4.3
Ausgangsschaltverhalten
closed:
11-12, 14-15, 17-18
open:
12-13, 15-16, 18-19
LED aus/out
-n
n =
Drehzahl / Speed
ns =
Eingestellte Schaltdrehzahl / Adjusted switching speed
27
U
= 12 VDC
R
0 V (GND)
ESL 93
ES 93R
closed:
12-13, 15-16, 18-19
open:
11-12, 14-15, 17-18
LED an/on
-ns (1,2,3)
0
Baumer_HOG10-ESL-T2_II_DE-EN (20A1)
6.2
ESL
6.2.4
ES 93 R
Relay modul (accessory)
6.2.4.1
Terminal assignment
Höhe = 55 mm
Kunststoffgehäuse für
Tragschienenmontage (EN 50022) IP20
Height = 55 mm
Plastic housing for
rail mounting (EN 50022) IP20
6.2.4.2
Block circuit diagram
5
~/+
9
=
6
= ~
~/-
8
2
11
13
12
14
3
16
15
17
19
4
18
6.2.4.3
Switching characteristics
closed:
11-12, 14-15, 17-18
open:
12-13, 15-16, 18-19
LED aus/out
+ns (1,2,3)
UB = 15...26 VDC
UB = 15...20 VAC
+n
MB071.2T2 - 11068774