Baumer Hubner HMC16 Series Mounting And Operating Instructions - Page 23
Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer Hubner HMC16 Series. Baumer Hubner HMC16 Series 44 pages. Encoder without bearings - incremental
6.8.2
Connection assignment
6.8.2.1
Output 1 „S": SinCos 1 V
Flange connector M23, 12-pin, male contacts, counter-clockwise
6.8.2.2
Output 1 „A": SinCos 1 V
Flange connector M23, 12-polig, male contacts, counter-clockwise
There is an inverted error signal via pin 7 available� In case of failure it has
an output of 0 V� In failure-free operation pin 7 have a ~5 V (RS422) TTL level
compared to pin 9�
Depending on version
2)
Only for power supply version „A" or „B"
9)
MB168T1EN - 11184527, 19A2, Baumer_HMC16-T1_II_EN
ELECTRICAL CONNECTION / OUTPUTS HMCP16
SS
Pin
Assignment
1
B–
2
dnu
3
dnu / R+
4
dnu / R–
5
A+
6
A–
7
dnu
8
B+
9
dnu
10
0 V
11
dnu
12
dnu / +UB
+ error output TTL level
SS
Pin
Assignment
1
B–
2
dnu
3
dnu / R+
4
dnu / R–
5
A+
6
A–
7
nE (TTL)
8
B+
9
0 V (nE)
10
0 V
11
dnu
12
dnu / +UB
2)
2)
(10���30 VDC)
9)
2)
2)
(10���30 VDC)
9)
19/40