7.4
Adjustment of the frequency output
Adjustment of the freqency output of output 1 (pin header 1) and output 2 (pin header 2)�
The frequency output can be adjusted via 3 different jumper positions on the correspon-
ding pin header on the electronic board, see
lower speed, see also
Jumper position frequency output, marked shows example of
0
rpm
kHz
-3000
0
15
+3000
25
-3000
50
0
100
+3000
150
= Factory setting
MB168T1EN - 11184527, 19A2, Baumer_HMC16-T1_II_EN
SETTINGS HMCP16 / ADjUSTMENT OF THE FREqUENCy OUTPUT
section
6.2.4�
1
rpm = Speed, kHz = Output frequency
rpm
kHz
5
-9000
5
0
15
+9000
25
-9000
50
0
100
+9000
150
section 7.2.1
y
2
rpm
kHz
-16000
5
-25600
0
15
+16000
25
+25600
-16000
50
-25600
0
100
+16000
150
+25600
or
7.2.2, to higher or
section
section
3
rpm
kHz
5
0
15
0
25
50
1
0
100
150
6.2.4�
27/40