ELECTRICAL CONNECTION / ADDITIONAL OUTPUT INCREMENTAL (OPTION)
5.3
Additional output incremental (option)
5.3.1
Output signals
At positive rotating direction
A+
A-
B+
B-
4)
R+
Zero pulse+
R-
4)
Zero pulse-
5.3.2
Trigger level
Trigger level:
High / Low:
Transmission length: ≤550 m @ 100 kHz
Output frequency
Trigger level:
High / Low:
Transmission length: ≤550 m @ 100 kHz (TTL) ǀ ≤350 m @ 100 kHz (HTL)
Output frequency
)
Electrically isolated: The output TTL/HTL (Vin = Vout) at the additional output
incremental 2 is electrically isolated and requires a separate power supply�
Only additional output incremental 2
4)
15/29
90°
TTL/RS422
≥2.5 V / ≤0.5 V
≤600 kHz
TTL/HTL (Vin = Vout)
≥2.5 V / ≤0.5 V (TTL) ǀ ≥Ub -3 V / ≤1.5 V (HTL)
≤600 kHz (TTL) ǀ ≤350 kHz (HTL)