Baumer PMG10P Mounting And Operating Instructions - Page 16

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer PMG10P. Baumer PMG10P 36 pages. Absolute encoder
Also for Baumer PMG10P: Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (32 pages), Operating Manual (44 pages), Operating Manual (44 pages), Operating Manual (40 pages), Operating Manual (40 pages), Operating Manual (40 pages), Operating Manual (36 pages)

Baumer PMG10P Mounting And Operating Instructions
ELECTRICAL CONNECTION / TERMINAL SIGNIFICANCE
5.

ELECTRICAL CONNECTION

5.1

Terminal significance

Ub
0V
A+
1)
A−
1)
B+
1)
B−
1)
R+
1)
R−
1)
nE+
nE−
PRE
DIR
SP+
2)
SP−
2)
SA
3)
SB
3)
D+
D−
C+
C−
dnu
* Depending on version
Additional output incremental (option)
1)
Speed switch (option)
2)
Programming interface (only PMG10P)
3)
13/29
Voltage supply
Ground
Output signal channel 1
Output signal channel 1 inverted
Output signal channel 2 (offset by 90° to channel 1)
Output signal channel 2 inverted
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / error output
System OK− / error output inverted
RESET (see also
section
Rotating direction (see also
DSL_OUT1 / speed switch (open collector* or solid state relay*)
DSL_OUT2 / speed switch (0V* or solid state relay*)
RS485+ / programming interface
RS485− / programming interface
SSI data+
SSI data−
SSI clock+
SSI clock−
Do not use
5.2.2)
section
5.2.3)