ELECTRICAL CONNECTION / TERMINAL SIGNIFICANCE
5.

ELECTRICAL CONNECTION

5.1

Terminal significance

Ub
0V
A+
A−
B+
B−
R+
R−
nE+
nE−
SP+
1)
SP−
1)
SA
2)
SB
2)
dnu
5.2
Output signals
Positive rotation direction when looking at the flange (see dimensions)
Speed switch (option)
1)
Programming interface (only PMG10P)
2)
16/32
Voltage supply
Ground
Output signal channel 1
Output signal channel 1 inverted
Output signal channel 2 (offset by 90° to channel 1)
Output signal channel 2 inverted
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / error output
System OK− / error output inverted
DSL_OUT1 / speed switch (open collector)
DSL_OUT2 / speed switch (0V)
RS485+ / programming interface
RS485− / programming interface
Do not use