Baumer PMG10P Mounting And Operating Instructions - Page 17

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer PMG10P. Baumer PMG10P 32 pages. Absolute encoder
Also for Baumer PMG10P: Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Operating Manual (44 pages), Operating Manual (44 pages), Operating Manual (40 pages), Operating Manual (40 pages), Operating Manual (40 pages), Operating Manual (36 pages)

Baumer PMG10P Mounting And Operating Instructions
5.3
Trigger level
Trigger level:
High / Low:
Transmission length:
Output frequency:
5.4
Programming interface (only PMG10P)
Via connection SA and SB, encoder parameters such as the number of pulses for the in-
cremental outputs 1 and 2 and/or the switch-off and switch-on speeds can be changed and
read out� With the Z-PA�SDL�1 WLAN adapter, available as accessory, see
encoder can be accessed via a web browser�
5.5
LED function displays
LED
INC1 (incremental
output 1)
INC2 (incremental
output 2)
Status
Speed
MB261EN - 11196414, 21A1, Baumer_PMG10-Inc_EN_202103_MI_11196414
TTL/HTL (Vin = Vout)
≥2.5 V / ≤0.5 V (TTL)
≥Ub -3 V / ≤1.5 V (HTL)
≤550 m at 100 kHz (TTL)
≤350 m at 100 kHz (HTL)
≤600 kHz (TTL)
≤350 kHz (HTL)
red
Undervoltage, overload,
over-temperature
Undervoltage, overload,
over-temperature
Internal error
Speed higher
switching speed (overspeed)
ELECTRICAL CONNECTION / TRIGGER LEVEL
green
OK
OK
OK
Speed lower
switching speed
section
6.1, the
17/32