Path runthrough time Measurement of the runthrough time (e.g. of a conveyor belt)
Example
Measurement using the Time measurement is initiated by a pulse at the input „F2/start" and
start and stop signal terminated by a pulse at the input „stop" . Both inputs respond to
Period duration Time measurement is started by the front pulse flank at the input
Pulse duration Time measurement is started by the front pulse flank at the input
Pulse rate measurement The pulse rate measurement is started by the first pulse at the input
5.3

Time measurements

When using the device as a time measurement system the user is
offered the following functions which can also be programmed in line
21. The time range and resolution are defined in line 38. The mea-
surement result is displayed at F3.
After time-out the display begins again at 00.00.00.
required for a certain path (from A to B) taking into account the
speed factor. The measurement result is displayed at F3. The speed
can be picked up using an incremental pulse encoder with two signal
tracks „A 90º B" on tachometer F1. In line 27 the required measure-
ment path must be pragrammed.
For this application F1 is bypassed. On selection of this application
F1 „OFF" is displayed. F2 can be used to display rpm or speed.
Circum.
Pulses/rev
(meas. wheel)
(sensor)
0,5 m
50
the front pulse flank. F2 indicated a currently running measurement
process.
„F2/start" and terminated with hte subsequent front pulse flank.
The measurement process can be interrupted by means of the
„stop" input (gate function). F2 indicates a currently running
measurement rement process.
„F2/start" and terminated with rear pulse flank. The measurement
process can be interrupted by means of the „stop" input (gate func-
tion). F2 indicates a currently running measurement process.
„F1/A" and terminated after recognition of a pulse rate.
Stand still recognition automatically ensures an update of the display
following every pulse rate. The pause time between pulse rates is
programmed at „time out" in line 29.
www.baumerivo.com
Scale
Path
(line 25)
(line 27)
50
10.00 m
= 100
0,5
TA201
Display range
(line 38)
10.00 m