Using the equipment
This welding unit takes the ambient temperature into account when calculating the
energy required to weld the fitting. It must therefore be allowed to reach ambient
temperature before use and must be at the same temperature as the fitting to be
welded.
• Switch the welder on and it will self test.
• The green power light will be on. Make sure no errors are showing.
• Connect the required colour welding cable to the socket, the indicator light will
show.
• YELLOW: 32mm – 160mm
Geberit, Wavin Waviduo, Akatherm, Valsir
• RED: 200mm – 315mm
Geberit
• BROWN: 200mm – 315mm
Wavin Waviduo
• BLUE: 200mm – 315mm
Akatherm, Valsir
• Connect the welding cable to the fitting.
• Press and hold-in the start button for two seconds to begin welding.
• The weld time will count up to 100% and the green light will come on.
• Any errors will be shown.
• Disconnect the welding cable from the fitting.
• To reset the welder press and hold-in the Start/Stop button for five seconds.
• To help avoid errors, use a good quality 2.5 kW / 3.0 kVA power generator to the
specifications TIN12/ECE3.