Baumer NE215 Operating Instructions Manual - Page 32
Browse online or download pdf Operating Instructions Manual for Cash Counter Baumer NE215. Baumer NE215 40 pages. Electronic preselection counter
Open interface description
32
7.10 Programming plan
Lines in italic* = Factory setting
Line 11-18
Status for line 11-18
0 * Parameter can be changed
1
Clearing and/or input disabled
2
Parameter is skipped
Line 21
Operating mode principal count system
0 * Progressive preselections
1
P1 Trailing preselection
Line 22
Not applicable
Line 23
Scaling factor batch counter
00
Minimum value
1 * Default value
99
Maximum
Line 24
Not applicable
Line 25
Not applicable
Line 26
Frequency batch counter counting
0 * 10 kHz
1
25 Hz
2
15 Hz
Line 27
Not applicable
Line 28
Not applicable
Line 29
Not applicable
Line 30
Reset batch counter
0 * Autom. reset and external static
1
Autom. reset and external differential
2
External static
3
External differential
Line 31
Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value
Line 32
Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value
Line 33
Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value
Line 34
Take-over of preselection P1, P2, B1
0 * In case of reset
1
After input
Line 35
Address for function key
0 * Function key not connected
:
8
Maximum value
NE215