Baumer NE215 Gebruiksaanwijzing - Pagina 32

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Baumer NE215. Baumer NE215 40 pagina's. Electronic preselection counter

Baumer NE215 Gebruiksaanwijzing
Open interface description
32
7.10 Programming plan
Lines in italic* = Factory setting
Line 11-18
Status for line 11-18
0 * Parameter can be changed
1
Clearing and/or input disabled
2
Parameter is skipped
Line 21
Operating mode principal count system
0 * Progressive preselections
1
P1 Trailing preselection
Line 22
Not applicable
Line 23
Scaling factor batch counter
00
Minimum value
1 * Default value
99
Maximum
Line 24
Not applicable
Line 25
Not applicable
Line 26
Frequency batch counter counting
0 * 10 kHz
1
25 Hz
2
15 Hz
Line 27
Not applicable
Line 28
Not applicable
Line 29
Not applicable
Line 30
Reset batch counter
0 * Autom. reset and external static
1
Autom. reset and external differential
2
External static
3
External differential
Line 31
Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value
Line 32
Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value
Line 33
Output time P1, (P2), (P3), B1
00.00 Maintained contact (LAtcH displayed)
0.25 * Default value
99.99 Maximal value
Line 34
Take-over of preselection P1, P2, B1
0 * In case of reset
1
After input
Line 35
Address for function key
0 * Function key not connected
:
8
Maximum value
NE215