Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
6.1.2
Beschreibung der Anschlüsse
+UB; +
; ; GND; 0V
;
K1; A; A+
K1; A; A-
K2; B; B+
K2; B; B-
K0; C; R; R+
K0; C; R; R-
Err; Err-
xxx
6.1.3

Ausgangssignale

Signalfolge bei positiver
Drehrichtung, siehe Abschnitt 5.
Sequence for positive rotating
direction, see section 5.
MB071.1T2 - 11069399
Betriebsspannung (für das Gerät)
Voltage supply (for the device)
Masseanschluss (für die Signale)
Ground (for the signals)
Erdungsanschluss (Gehäuse)
Earth ground (housing)
Ausgangssignal Kanal 1
Output signal channel 1
Ausgangssignal Kanal 1 invertiert
Output signal channel 1 inverted
Ausgangssignal Kanal 2 (90° versetzt zu Kanal 1)
Output signal channel 2 (offset by 90° to channel 1)
Ausgangssignal Kanal 2 (90° versetzt zu Kanal 1) invertiert
Output signal channel 2 (offset by 90° to channel 1) inverted
Nullimpuls (Referenzsignal)
Zero pulse (reference signal)
Nullimpuls (Referenzsignal) invertiert
Zero pulse (reference signal) inverted
Fehlerausgang
Error output
Nicht benutzen
Do not use
Baumer_HOG10-FSL-T2_II_DE-EN (17A2)