Activating "Fresh Filtered Ice and Water"
If you purchased your dispenser with a Follett filter, the filter display indicator
activation has been preset at the factory.
If you are using an "after market filter," an adjustment may be made to
activate the "Fresh Filtered Ice and Water" display.
1. Remove the front panel as explained in Accessing Internal
Components.
2. Remove top panel (Fig. 13.1).
Note: For 15 Series dispensers, the right side panel must also be
removed.
3. Remove (1) screw and top of control board enclosure (Fig. 13.2).
4. Locate the DIP switches on the dispenser's control board (Fig. 14).
Use a fine-pointed object to move the "Filter" DIP switch (DIP switch
#3) to the ON position.
Deactivating the Six-Month Maintenance/Filter Change Reminder
1. Use a fine-pointed object to move the "PM" DIP switch (DIP switch
#8) to the ON position.
Not used (OFF position)
Ice only
No internal filter
Not used (OFF position)
Not used (OFF position)
15 minute delay
Not used (OFF position)
Six-month PM enabled
14
Dispenser and Ice Machine - 115 V, 230 V, 220 V
OFF
ON
Ice and water
Internal filter supplied or to display "Fresh Filtered"
30 minute delay
Six-month PM disabled