Input connector:
Modified 7-pin female XLR-connector
Output connector:
Standard 3-pin male XLR-connector
Operating temperature range:
-10° C to +55° C (+14 to 131° F)
Mains voltage: 1
00 VAC – 127 VAC and 200 VAC – 240 VAC, 50 Hz and 60 Hz
Power consumption:
Maximum 15 W
Note:
The specifications and tolerances listed, as well as performance and
stability of the HMA5000, are only guaranteed when using the dedi-
cated cables from DPA Microphones.
CHANGING THE MAINS FUSE IN HMA5000
The HMA5000 is protected with a 250 mA slow blow fuse.
The fuse is rated to give adequate protection at both 120 VAC and
230 VAC. Only the correct replacement fuse must be fitted.
WARNING! Disconnect the HMA5000 from the mains supply before
removing the instrument housing.
1. The mains fuse holder is located on the printed circuit board of the
HMA5000. To gain access, the front and rear face panels of the
HMA5000 should be removed by pulling the top and bottom bezels
off the clip on frame outwards (as shown).
8
2. Unscrew the two retaining screws on the metal casing of the
HMA5000
3. Gently pull out the assembly.
4. Remove the Mains Fuse with a screwdriver and insert a new Mains
Fuse likewise.
9