Draper 65084 Original Instructions Manual - Page 13
Browse online or download pdf Original Instructions Manual for Sander Draper 65084. Draper 65084 20 pages. Dual action air composite sander
Also for Draper 65084: User Manual (16 pages)
8. Maintenance and Storage
Important: ALWAYS ensure that the air supply is
disconnected from the tool before performing any
maintenance or storing the product.
8.1 General Maintenance
• Keep the air line inlet, exhaust and dust outlet free
from dust, debris and other obstructions.
• Regularly check the tightness of the backing plate
to ensure a firm fit that does not exhibit resistance
when rotated.
• Periodically check the sanding pads and backing
sheets for damage or wear and replace them
as necessary.
• Keep the hook and eye pad of the backing plate
free from debris to ensure a secure grip on the
sanding pad.
• Lubricate the mechanism by pouring a few drops
of air tool oil into the air line inlet before and after
every use.
• Ensure that the air line is sufficiently lubricated and
apply additional lubrication into the air line inlet if
evidence of binding occurs.
• Maintain the air line appropriately:
− Drain the compressor reservoir and air
lines of condensate and dispose of the
liquid appropriately.
− Drain the water trap.
− Drain and fill the combined separator filter,
regulator and lubricant reservoir.
− Ensure that the air line pressure is appropriate for
the tool.
8.2 Replacing the Backing Plate
The backing plate should be replaced if it becomes
damaged, can no longer be sufficiently fastened, or no
longer grips the sanding pads securely.
1. Lift the rubber shroud (7) slightly and locate the
spindle locking nut.
2. Insert the 24mm spanner (C) under the shroud and
locate it around the spindle locking nut.
(7)
(C)
Fig.
7
3. Use the spanner to hold the spindle locking nut in
place and rotate the backing plate (2) forwards as
indicated on the shroud.
(2)
Fig.
8
4. Install a new backing plate onto the spindle, using the
spanner to hold the locking nut in place and rotating
the plate in the reverse direction.
CAUTION! DO NOT overtighten the backing
plate as this may restrict the motion of
the plate.
Important: ALWAYS ensure that the spanner has been
removed before reconnecting the air line.
– 13 –
EN