IR3S – OPERATIONS
Turn the main switch on. This will initiate the electronics.
Four dots will sequentially blink to indicate the start-up.
Next the top display will show 1P (1-phase). The lower
display shows the supply frequency 50 or 60 Hz.
When the start-up sequence is over, the displays show
the active curing times in minutes. Flash-off at the upper
and full bake at the lower.
Use the + and - buttons below the displays to change
the settings. Pressing the buttons continuously will
rapidly increase the setting. Each timer can be set
between 0 and 30 min. The settings will remain even
after power-off and serve as default for the next curing
operation.
Start the curing by pressing the On/Off button. The
active timer will flash and the heater will switch off
automatically when the set times have elapsed.
After idling for 30 minutes, the unit enters stand-by
mode when a dot in each display flashes. Pressing any
button will activate the unit again.
www.carlisleft.com
TRU CURE IR3S – OPERATING INSTRUCTIONS
FLASH OFF TIMER
FLASH OFF SETTINGS
FULL BAKE TIMER
FULL BAKE SETTINGS
ON/OFF BUTTON
MAIN SWITCH – LOCATED ON THE
RIGHT HAND SIDE
Minimum curing distance is 50 cm and optimal curing
distance is 60 cm.
The FLASH OFF timer controls the duration of the half
power output of the emitters. The FULL BAKE timer
controls the duration of the full power output of the
emitters. If both FLASH OFF and FULL BAKE timers
are used, the FLASH OFF timer will count down first
and upon switching off it will engage the FULL BAKE
timer automatically.
To stop the unit before the time is out, press the On/
Off button.
Altering timers is possible even during curing.
If the temperature inside the control unit rises over
65°C (149°F) , the unit switches off. The upper
display will show Ot (over temperature) and the
lower the actual temperature. Automatic reset when
the temperature falls below 55°C (131°F) and the
unit is ready for operation again.