Drazice OKC 200 NTRR / BP Operating And Installation Manual - Page 6

Browse online or download pdf Operating And Installation Manual for Boiler Drazice OKC 200 NTRR / BP. Drazice OKC 200 NTRR / BP 13 pages. Stationary water heaters
Also for Drazice OKC 200 NTRR / BP: Operation And Installation Manual (17 pages), Operation And Installation Manual (12 pages), Operation And Installation Manual (19 pages), Operation And Installation Manual (20 pages), Operation And Installation Manual (20 pages), Operation And Installation Manual (18 pages), Operating And Installation Manual (20 pages), Operation And Installation Manual (18 pages)

Drazice OKC 200 NTRR / BP Operating And Installation Manual
OKCE 300 NTR/2,2 kW, OKCE 300 NTR/3-6 kW
OKC 300 NTR/BP
6.

HSW (Hot Service Water) TEMPERATURE CONTROL

a)
HSW TEMPERATURE CONTROL for 300 litre heaters – the panel is a part of the heater
Each heater has a separate HSW temperature control for every exchanger. The temperature of water can be set
between 5-74°C.
A vertical double thermowell is welded onto the tank shell for the controller sensors, for each exchanger. If an
external temperature control is used, the thermowell is adapted for 7 and 10 mm diameter probes. The probes can
be shifted vertically for proper adjustment of the entire system.
Exchanger control panels:
NTRR top exchanger control
panel:
Capillary thermostat and
thermometer
*
OKCE 300 NTRR/2,2 kW, OKCE 300 NTRR/3-6 kW
OKC 300 NTRR/BP
NTR & NTR lower exchanger
control panel:
kapilárový termostat
6 0
6
Cover panel if external HSW
temperature control is used