Carmanah E Series Install Manual - Page 7
Browse online or download pdf Install Manual for Security System Carmanah E Series. Carmanah E Series 20 pages. Rrfb mast arm kit
Also for Carmanah E Series: Quick Start Manual (20 pages), Install Manual (16 pages), Energy Management System Replacement Manual (12 pages), User Manual (18 pages), Replacement Manual (9 pages), Install Manual (18 pages)
3"
Discard
leftover
wire
Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 | [email protected] | carmanah.com
Prepare AI Harness
If the AI Integration Kit was ordered with a
Carmanah E/F system, skip to step 15.
• Obtain AI harness.
• Cut and remove terminals of the five wires shown
1
(violet, blue, black, red and yellow).
• Leave green wire ring terminal intact (not shown).
• Cut yellow wire to same length as black wire.
• Cut a three-inch section of yellow wire and strip each
end 0.35", for use later.
2
• Install provided heat-shrink tubing around the five wires
4.25" from end of black wire (other wires will end up
3
being longer).
• Use heat gun to affix the heat shrink tubing.
• Strip insulation of the five wires 0.35".
4
APPLIED INFORMATION (AI) INTEGRATION KIT INSTALL GUIDE
E/F Series
4.25"
Page 7