Also for Bosch 6 Series: User Manual (24 pages), Instructions For Installation And Use Manual (20 pages), Instructions For Installation And Use Manual (20 pages), Instruction Manual And Installation Instructions (48 pages), Instruction Manual (16 pages), Instruction Manual (48 pages), Installation Instructions Manual (27 pages), Instruction Manual (12 pages), Installation And Operating Instructions Manual (36 pages), Instruction Manual (16 pages), Instructions For Installation And Use Manual (16 pages), Instructions For Use Manual (29 pages), User Manual And Installation Instructions (16 pages), Information For Use (32 pages), Quick Reference Manual (2 pages), Quick Reference Manual (2 pages), Information For Use (28 pages), User Manual (23 pages), Instruction Manual (24 pages), Installation Instructions And Instructions For Use (24 pages), Information For Use (16 pages), User Manual (36 pages), User Manual (32 pages), User Manual (28 pages), User Manual (28 pages), Instruction Manual (28 pages), Information For Use (20 pages), Instruction Manual (28 pages)

Bosch 6 Series Instructions For Installation And Use Manual
5Installation
P reparing for installation
I n s t a l l a t i o n
Caution!
Ensure that there are no electrical wires, gas pipes or
water pipes in the area where holes are to be drilled.
If the extractor hood is to be operated in exhaust-air
mode, a flue duct must be fitted.
If the extractor hood is to be operated in air-recirculation
mode, an optional accessory must be fitted. To do this,
refer to the installation instructions provided. The flue
duct does not need to be fitted for air-recirculation
mode.
Determine where the extractor hood should be
1.
positioned and lightly mark where the lower edge of
the appliance should be on the wall. Determine
where the middle should be based on the hob.
We recommend fitting the extractor hood such
Note:
that the lower edge of the glass screen is in line with
the lower edges of the adjacent wall-hung cabinets.
Make sure that the specified safety clearances from
the hob are complied with.
Place the template against the line drawn on the wall
2.
and fasten it in place. Mark where the screws should
be inserted.
To fit the flue duct, the template must be cut along
the marked cut line.
Drill 8 mm diameter holes to a depth of 80 mm for
3.
fastening the appliance, remove the template and
press in the wall plugs flush with the wall.
Installation en
17