Caroma G Series Installation And Maintenance Instructions Manual - Page 11

Browse online or download pdf Installation And Maintenance Instructions Manual for Plumbing Product Caroma G Series. Caroma G Series 16 pages. Electronic soap dispenser
Also for Caroma G Series: Installation And Maintenance Instructions Manual (16 pages), Installation And Maintenance Manual (16 pages), Installation And Maintenance Manual (17 pages)

Caroma G Series Installation And Maintenance Instructions Manual
sETTINGs ADjusTMENT
lock ouT TiME: It is possible to program a lock out time in caroma
products upon request. this lock out time allows a user to activate
the mixer or tap, only after a specific amount of time has passed.
If a specific lock out time was preset in a caroma product as
default, and you would like to deactivate it, press the lock button.
Wait until a quick flashing of the red light of the sensor eye is
perceived. then press + to activate the lock out time or – to
deactivate it.
to activate it again, press the lock button and without releasing it,
press the + button once.
TEMPorary oFF FuncTion: this function is ideal to perform any
kind of activity in front of the sensor without operating the system
(for example, cleaning).
Mixer or tap will remain shut for 1 minute when this button is
pressed once. to cancel this function and to return to normal
operation press the on/off button again or wait 1 or 2 minutes
depending on the product.
rESET BuTTon: this function allows the sensor to return to the
original factory preset settings.
If required, press the Reset button and without releasing it, press
the + button once.
11