Mounting Preparation
Mounting Preparation
Compac Industries Ltd.
The ComTank unit needs to be mounted to a flat, steel plate prepared with a cut-out
and fastener holes as per drawing below. A steel template marked with the
appropriate dimensions is available as an option from Compac. Holes are drilled to
clear M6 (6 mm diameter) studs.
Ensure your mounting plate is thin enough to allow you to put the washers and nuts
on the end of the 20mm long studs.
The plate the ComTank is mounted on should be rust protected if it is not made from
stainless steel.
Ensure there is sufficient access to allow the installer and service people to
comfortably remove the cover from the rear of the unit and perform service work. A
minimum clearance of 850 mm is recommended.
Figure 1 ComTank Panel Cutout. Note: Do not cut to outer lines.
If installing ComTank pumps as part of the installation, refer to the ComTank Pump
Installation Sheet for pump, display and nozzle holder mounting instructions.