Software Changes

Menu Structure in the K factor Menu
Solenoid Test Function
Error Messages
Compac Industries Ltd.
Unused menu options have been removed and the following menu
structure is all that will be shown:
Density
Set to the local density value
Lo Flo
Normally set to 2.0 for a car dispenser
Hi Flo
Normally set to 30.0 for a car dispenser
B
Normally set to 0000
C
Normally set to 00062
As calibration is now carried out in the Micromotion meter
and not in the C4000, there is no K-factor setting available.
To enable the test function, set the b configuration to 0001.
The displays will show Side A/B and the state of the solenoid outputs.
Use the nozzle switch to step through each of the solenoid outputs one
at a time. The display will indicate whether the solenoid number
indicated is off or on.
There are two additional Error Messages Available for the Micromotion
meter
Error 50 - Communications error with CNG50 meter
Error 51 - Meter not ready / Meter error
These codes have not changed from a standard CNG dispenser with
Compac KG80 Meters