Shutting the Dragon Off
1. Turn the HEAT switch to "Off" but leave the unit
plugged in. NOTICE: Do not turn the Dragon off by
simply unplugging the unit, as this could cause
thermal overload. You must allow time for the fan to
cool the heat exchanger.
2. Leave the unit plugged in for at least 10 minutes
while the fan cools the heat exchanger. The fan will
turn off and on during the cooling cycle.
3. After a minimum 10-minute cooling period, you may
unplug the unit.

Special Instructions

Preventing thermal overload
If the temperature of the heat exchanger exceeds 212°F
(100°C), the Dragon will automatically shut down due to
thermal overload and must be reset before it will start
again. The most common cause of thermal overload is
restricted airflow. To help prevent thermal overload, you
should:
Make ducting runs as straight as possible
Keep the ducting free of debris and unobstructed
Keep the air intake grill unobstructed
Restarting after thermal overload
If the Dragon shuts off due to thermal overload, follow
these instructions for restarting.
1. Wait 10 minutes to let the Dragon cool down.
2. Make certain that ducting runs are straight and
unobstructed. Make certain the air intake is
unobstructed.
3. Unscrew the plastic cover for the Temperature-
Limiter Reset Button located near the HEAT and
FAN switches.
Remove the plastic cover for the Temperature-Limiter Reset Button
07-00407 E 08/2006
Copyright 2006 Dri-Eaz Products, Inc.
4. Using a pen or a pencil, depress the Temperature-
Limiter Reset Button.
Use a pen or pencil to depress the Temperature-Limiter Reset Button
4. Replace the plastic cover on the Temperature-
Limiter Reset Button.
5. Make certain the HEAT switch is turned on.
If the heater continues to shut off due to thermal
overload, contact the Dri-Eaz Service Department at
1-888-867-3235.
Restarting after running out of fuel
If the Dragon runs out of fuel, it will automatically shut
off.
NOTICE: Check internal tank fuel level at least every
8 hours to avoid running out of fuel, as the unit may
require servicing to be restarted.
Follow these instructions for restarting:
1. Turn the HEAT switch off and unplug the Dragon.
WARNING! Allow the Dragon to cool for at least 10
minutes.
2. Refill the fuel tank with diesel #2 fuel oil only. The
internal tank has a 9.3-gallon capacity. Do not
overfill. Turn off power and allow unit to cool before
refueling.
3. Plug the Dragon back in to a grounded outlet using
an appropriately rated extension cord.
4. Turn the HEAT switch to on.
8