Electrolux MCH 660 Instruction Book - Page 11
Browse online or download pdf Instruction Book for Ventilation Hood Electrolux MCH 660. Electrolux MCH 660 17 pages.
Please ensure that when the appliance is
installed it is easily accessible to an
engineer in the event of a breakdown.
All installations must comply with the local
authorities requirements for the discharge of
exhaust air.
Incorrect installation may affect the safety of this
cooker hood.
Installation Requirements
Before installation check the wall to which the
cooker hood is to be fitted for electric cables,
water or gas pipes.
If it is necessary to fix the hood to a hollow
construction plaster or partition board
structure then it should be sufficiently
reinforced to be quite rigid in the area of the
cooker hood keyhole fixing screws, and the
appropriate rawl plugs used for this type of
fixing (not supplied).
Ducting
The ducting must be fire retardant 100mm (4ins)
in diameter and the length should be no
more than:
3 metres with one 90° bend
2 metres with two 90° bends
Bends of more than 90° will reduce the
efficiency of the hood and reduce the airflow.
INSTALLING THE COOKER HOOD
11