Electrolux U24211 EFT 635 Operating And Installation Instructions - Page 11
Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Electrolux U24211 EFT 635. Electrolux U24211 EFT 635 15 pages. Electrolux range hood operation and installation manual
Technical Specifications
Model
Dimensions (in cm):
Height (cm)
Width (cm)
Depth (cm)
Maximum absorbed power: 160W
Motor absorption:
Lighting:
Length of the cable:
Electrical connection:
Subject to change without notice.
Installation
Unpacking
Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the company responsible for the
transportation.
Damages, faults and eventually missing details
should immediately be reported to the retailer.
Take care of the packing materials so that small
children cannot play with them.
Fitting
The hood is to be mounted on the wall.
When installed, the hood must be not less than 60
cm. above electric burners or 65 cm. above gas or
mixed-fuel burners.
The hood can be installed above these heights but
for optimum performance it should be installed at
the distance quoted for the appropriate heat source.
Electrical connection (not for UK)
Safety warnings for the electrician
Before connecting the appliance to the power
supply, check that the voltage indicated on the
rating plate corresponds to the mains power supply
available. Appliances fitted with a plug can be
connected to any standard power socket within
easy access.
Should it be necessary to provide a fixed
connection, the hood must only be installed by an
electrician authorised by the local electricity board.
When installing, a double pole switch with a
distance of at least 3 mm between contacts must be
provided.
Fixed connection of the appliance must only be
carried out by an authorised electrician.
EFT 630 - EFT 635
13
59,8
51
1 x 120 W
1 x 40 W
150 cm
220 - 240 V
EFT 530 - EFT 535
13
49,8
51
160 W
1 x 120 W
1 x 40 W
150 cm
220 - 240 V
Fig. 7 - Fitting
Electrical connection for UK only
Safety warnings for the electrician
Connect the hood to the mains supply via a double
pole switch which has 3 mm minimum separation
between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom
only:
- the wire which is coloured blue must be
connected to the terminal which is marked with
the letter N or coloured black, -
- the wire which is coloured brown must be
connected to the terminal which is marked with
the letter L or coloured red.
40
EFT 630/GB - EFT 635/GB
13
59,8
51
180 W
1 x 120 W
2 x 40 W
150 cm
220 - 240 V
Min
Min
65 cm
60 cm