DROPSA 3905000 User Operating And Maintenance Manual - Page 6

Browse online or download pdf User Operating And Maintenance Manual for Water Pump DROPSA 3905000. DROPSA 3905000 13 pages.

DROPSA 3905000 User Operating And Maintenance Manual
6.3 MINIMUM LEVEL CONNECTION
The connection at the minimum level is done using connector 2 based on the following table:
n°2 M3 Screw
6.4 OPTICAL LEVEL CALIBRATION
The level is tested and calibrated with oil by Dropsa, however is recommended before starting the pump to following the
procedure below:
1)
Fill the reservoir;
2)
Open the front regulating hole;
3)
Turn the level adjustment screw using a screwdriver, until the green led on the level is off (see the image below);
4)
Turn the screw in opposite way until the green led is on.
At the end of this procedure the level is correctly set. It is possible to re-do the calibration following the same procedure above.
6
VIP5 Dropsa (Optional)
Terminal streap M2
n° PIN
10
5
4 / NC
4 / NC
CONNECTION TABLE
(version with optical level)
1
V+ (8÷28 Vdc)
2
V- (GND)
3
Out N
Out P
4
Connection pin when it is used Dropsa
VIP5 Control Device
Note: Set PIN 4 – M2 connection
exclusively on Out N or on Out P.
Note: Set the NC level in VIP5
parameters
CONNECTION TABLE
(version with floating switch)
1
2
3
4
Green led
COM
NC
NO
-