3.2
Enroll & Program Wireless Keys
For wireless keys to work on the system, you need to enroll them and then program the function
buttons, if the default values are not the functions desired. Wireless keys are not assigned to
zones and require no zone programming. You can enroll up to 8 wireless keys on the system.
Enroll Wireless keys
1. At a system keypad, enter [✱][8][Installer's Code] to go to the installer's
programming section.
2. Enter programming section [804].
3. Enter a 2-digit number [41]-[48] to program the wireless key serial number. These
numbers correspond to wireless key numbers 01- 08.
4. Enter the key's ESN. The entry must be six digits. If an older key with a 5-digit
ESN is being enrolled, add the digit [0] to the beginning of the ESN (e.g.,
ESN=61234, enter 061234).
5. The key is now enrolled on the system. Record the serial number and the assigned
slot number in the programming worksheets in the back of this manual.
6. Repeat steps 3 - 5 until all wireless keys have been enrolled.
7. ( ( ( ( ( PC5020/P-8+/
PC5020/P-8+/
PC5020/P-8+/
PC5020/P-8+/
PC5020/P-8+/PC501
PC501X/P832/P832DL
PC501
PC501
PC501
assigned to Partition 1. To assign keys to Partition 2, enable the appropriate
options in programming section [91].
NOTE
NOTE
NOTE: A wireless key can only be assigned to one partition.
NOTE
NOTE
8. To exit press [#].
Program the (P)WLS909-433 or (P)WLS919-433 Function Buttons
(P)WLS909-433 and (P)WLS919-433 wireless keys have four programmable function
buttons. Default functions have been assigned, but you may program other functions if
desired. After the functions are programmed, when you press and hold one of the four
buttons for one second, the system will execute the programmed function.
For systems using partitions (PC5020/P-8+/PC501X/P832/P832DL only): All wireless
keys assigned to Partition 1 will have the four functions programmed in section [61]. All wireless
keys assigned to Partition 2-8 will have the four functions programmed in section [62-68]. For
example, if function button 1 in Section [61] is programmed for Stay arming, then pressing the
first button on wireless keys assigned to Partition 1 will Stay arm Partition 1.
NOTE
NOTE
NOTE: Wireless keys will not work when the partition they are assigned to is being
NOTE
NOTE
accessed for zone bypassing or programming.
1. At a system keypad, enter [✱][8][Installer's Code].
2. Enter programming section [804].
3. Enter programming section [61] to [68] for partitions 1 to 8.
4. For each of the 4 function buttons, enter the 2-digit number of the function you
want to select. See the programming worksheets in the back of this manual for a
list of function key options.
5. Record your programming choices in the worksheets in the back of the manual.
6. To exit press [#].
3.3
Identified Wireless Keys
Reporting by the system of openings/closings by individual wireless keys and command
output [✱][7] activation by wireless key buttons may be supported on certain control
panels. To do this, the system will reserve access codes 17 – 24 for wireless keys 01-08
respectively. You must program one access code for each wireless key (using [✱][5]
access code programming) for this feature to work correctly.
NOTE
NOTE: Program these access codes on the system after you have connected the PC5102-
NOTE
NOTE
NOTE
433 to the Keybus (see section 2.4).
Refer to your system Installation Manual for information on access code programming.
X/P832/P832DL only)
X/P832/P832DL
X/P832/P832DL
X/P832/P832DL
firealarmresources.com
only) By default, all wireless keys are
only)
only)
only)
4