DSC PowerSeries Product Summary Sheet - Page 8
Browse online or download pdf Product Summary Sheet for Security System DSC PowerSeries. DSC PowerSeries 20 pages. Telephone interface & automation control module
Also for DSC PowerSeries: User Manual (20 pages)
Step 3 - Thermostat 1 Day Occupancy Setting PGM Output – Escort Section [804]
Program data [03]. The Escort will adjust the temperature to the value programmed for the Day Occupancy
Setting when PGM Output [03] is activated by the panel.
Step 4 – Thermostat 1 Night Occupancy Setting Output Option – Escort Section [808]
Program data [01] for output control only. The user will always have manual control as well.
Step 5 - Thermostat 1 Night Occupancy Setting PGM Output – Escort Section [809]
Program data [05]. The Escort will adjust the temperature to the value programmed for the Night
Occupancy Setting when PGM Output [05] is activated by the panel.
Step 6 – Thermostat 1 Away Occupancy Setting Output Option – Escort Section [818]
Program data [01] for output control only. The user will always have manual control as well.
Step 7 - Thermostat 1 Away Occupancy Setting PGM Output – Escort Section [819]
Program data [04]. The Escort will adjust the temperature to the value programmed for the Away
Occupancy Setting when PGM Output [04] is activated by the panel.
Step 8 – PGM Output 03 to 10 Programming – Panel Section [010], [143]
Three different outputs are needed; stay arm, away arm and disarm. To get an output to activate for disarm
status, we must 'invert' an output programmed for armed status.
Section [010] - Program the following:
PGM 03
PGM 04
PGM 05
Section [143] – Program the following:
Turn Option [1] ON
Turn Option [2] ON
Turn Option [3] OFF
Operation:
When the panel is armed in the 'stay' setting, the panel will activate PGM Output [05]
and the Escort will adjust the temperature to the value programmed for the Night
Occupancy Setting. When the panel is armed in the away setting, the panel will activate
PGM Output [04] and the Escort will adjust the temperature to the value programmed for
the Away Occupancy Setting. When the panel is disarmed, the panel will activate PGM
Output [03], and the Escort will adjust the temperature to the value programmed for the
Day Occupancy Setting.
data [05]
data [05] for 'Armed Status'
data [17]
data [17] for 'Away Arm'
data [18]
data [18] for 'Stay Arm'
enable partition 1
enable partition 2
will 'invert' the output – instead of activating when
the panel is armed, the output will activate when the
panel is disarmed.